Federal Heights, CO Roofing Codes

Federal Heights, Colorado follows the 2015 IBC codes and the 2015 IRC.

Items that the County Requires are below.
Max number of layers: 1
reroof with shakes:
Ice and water required: NO
Rake or Eave metal required: Yes
Rolled roofing allowed:
Felt: double felt required between 2/12 and 4/12
Cricket required for chimney 30" and over: Yes
Planked decking must not exceed 1/4" gaps
No 3-tabs--See approved shingle list (click on roofing handout below and go to page 3)

required inspections:
Sheathing if new is applied
Mid roof
Final


Link to ICC for Federal Heights, CO (Click Here)
Showing Federal Heights, CO has adopted 2015 IBC/IRC (Click Here)
Federal Heights, CO roofing handout (Click Here)